Backwashing In backwashing, the transmembrane pressure is periodically inverted by the use of a secondary pump, so that permeate flows back into the feed, lifting the fouling layer from the surface of the membrane. Backwashing is not applicable to spirally wound membranes and is not a general practice in most applications. (See
Clean-in-place)
Alternating tangential flow (ATF) A
diaphragm pump is used to produce an alternating tangential flow, helping to dislodge retained particles and prevent membrane fouling.
Repligen is the largest producer of ATF systems.
Clean-in-place (CIP) Clean-in-place systems are typically used to remove fouling from membranes after extensive use. The CIP process may use detergents, reactive agents such as
sodium hypochlorite and acids and alkalis such as
citric acid and
sodium hydroxide (NaOH). Sodium hypochlorite (bleach) must be removed from the feed in some membrane plants. Bleach oxidizes thin-film membranes. Oxidation will degrade the membranes to a point where they will no longer perform at rated rejection levels and have to be replaced. Bleach can be added to a sodium hydroxide CIP during an initial system start-up before spirally-wound membranes are loaded into the plant to help disinfect the system. Bleach is also used to CIP perforated stainless steel (Graver) membranes, as their tolerance for sodium hypochlorite is much higher than a spirally-wound membrane. Caustics and acids are most often used as primary CIP chemicals. Caustic removes organic fouling and acid removes minerals. Enzyme solutions are also used in some systems for helping remove organic fouling material from the membrane plant. The pH and temperature are important to a CIP program. If pH and temperature are too high the membrane will degrade and flux performance will suffer. If pH and temperature are too low, the system simply will not be cleaned properly. Every application has different CIP requirements. e.g. a dairy
reverse osmosis (RO) plant most likely will require a more rigorous CIP program than a water purification RO plant. Each membrane manufacturer has their own guidelines for CIP procedures for their product.
Concentration The volume of the fluid is reduced by allowing permeate flow to occur. Solvent, solutes, and particles smaller than the membrane pore size pass through the membrane, while particles larger than the pore size are retained, and thereby concentrated. In bioprocessing applications, concentration may be followed by diafiltration.
Diafiltration In order to effectively remove permeate components from the slurry, fresh solvent may be added to the feed to replace the permeate volume, at the same rate as the permeate flow rate, such that the volume in the system remains constant. This is analogous to the washing of filter cake to remove soluble components. Dilution and re-concentration is sometimes also referred to as "diafiltration".
Process flow disruption (PFD) A technically simpler approach than backwashing is to set the transmembrane pressure to zero by temporarily closing off the permeate outlet, which increases the attrition of the fouling layer without the need for a second pump. PFD is not as effective as backwashing in removing fouling, but can be advantageous. == Model-based fouling control ==