The ability to control the
electrode potential for electro-switchable biosurfaces facilitates several different applications. One example is the field of
molecular electronics, for instance the investigation of DNA-mediated charge transfer. Another application is the analysis of molecular interactions. To that end, the DNA strand is labeled with a
fluorescent dye. Excited fluorescent dyes can transfer energy to metal. Consequently, the fluorescence is
quenched in proximity to the metal electrode. To measure interactions, a
ligand is additionally attached at the head of the DNA molecule and the interacting
analyte is flushed across the biosensor. Two different measurement modes can be performed with the biosensor, a static mode and a dynamic mode. In static mode, the potential applied to the electrode is fixed, keeping the DNA molecule in an upright position. Binding of the analyte to the ligand will change the local environment of the fluorescent dye and thereby quench its fluorescence. The static mode can also be used to measure the activity of
enzymes like
polymerases that influence the structure of the DNA molecule. In dynamic mode, the potential applied to the electrode is oscillating, thus the DNA molecule switches between the upright and the horizontal position. Binding of an analyte will change the size of the attached complex. Consequently, the hydrodynamic friction will change and the DNA molecule will move through the buffer with a different speed. This speed change can be used to investigate size changes or conformational changes induced by the binding of the analyte. The application of electro-switchable biosurfaces as a sensor for molecular interactions is also known as switchSENSE technology. It belongs to the category of microfluidic surface-bound methods to measure molecular interactions. A similar application in this category is
surface plasmon resonance (SPR), where a thin gold film on top of a glass slide is the sensor surface. In SPR, the gold film can additionally be modified with SAM or other specific layers. One difference to electro-switchable biosurfaces is that no potential is applied to the SPR surface. In contrast to surface-bound methods, there are also in-solution methods to measure molecule interactions, for example
isothermal titration calorimetry (ITC). The
electric potential cannot only be used to control the movement of the DNA strands, but also to control the release of the molecules into solution. This has possible applications in the field of
gene therapy since it might enable the delivery of genetic material to specific locations. ==See also==