The most common use for this technique is controlling the path of a stream of electrons in a vacuum. One application is in small
cathode-ray tubes for
oscilloscopes. In these tubes the electric field is created by two sets of paired electrodes, mounted at right angles, that the electron stream flows between. This arrangement allows independent deflection of the beam in two dimensions (usually perceived as up/down (vertical) and right/left (horizontal)). The electrodes are commonly called
deflection plates. Traditionally, the electrons pass through the vertical deflection plates first, yielding slightly higher sensitivity because of the longer travel time from the vertical deflection plates to the phosphor screen as compared to the horizontal deflection plates. In very high speed oscilloscopes, the deflection plates were often complex structures, combining a series of sub-plates with an electrical
delay line. By matching the propagation speed of the electrical signal with the transit speed of the electrons, maximum bandwidth (frequency response) was achieved. The technique works well whenever a sufficiently uniform stream can be created, as discussed above. Therefore, it has been used in controlling macroscopic particle streams, for instance in
fluorescence-activated cell sorting, as well. Another application was in one type of
inkjet printer. Electrostatic deflection is very useful for small deflection angles but is well known to be inferior to magnetic deflection for deflecting a charged particle beam into large angles - say over 10 degrees. The reason is that deflection aberrations become large as the deflection angle increases. This reduces the ability to finely focus the beam. Also in electrostatic deflection it has long been the practice to inject the beam midway between the charged deflection plates so as to avoid the fringe fields as much as possible. However it was found by computation methods that deflection aberrations would be significantly reduced if the beam were injected offset toward the attracting plate. That way the beam tends to follow equipotentials and the deflection force is normal to the beam direction. Thus offset, all the electrons in the beam are deflected into the same angle. There is an induced astigmatism that is correctable. This deflection idea has been tested and verified. Deflection angles of 50 degrees are reportedly possible without measurable deflection aberration. Optimal injection offset is approximately 1/3 of the plate gap toward the deflecting plate. The useful beam diameter is also approximately 1/3 of the gap. ==References==