Electric Field and Langmuir Probe Experiment The FAST electric field instrument has ten sensors, two on each of the four 29 m radial wire booms (at 24 m and 29 m) and one on each of the two rigid 3 m axial booms. All except the four outermost sensors can also operate as current collecting Langmuir probes. Similar instruments were flown on S3-3, ISEE-1, CRRES, Polar and Cluster. The instrument is designed to provide the following: a vector measurement of the electric field from DC to about 20 kHz over a dynamic range of 0.1 mV/m to 1 V/m with a sampling resolution of 0.03 ms; AC electric field waveform measurements up to 2 MHz with a sampling resolution of 32 ms; continuous monitoring of the dominant frequency and amplitude of high-frequency waves with a time resolution of 0.03 ms; measurement of the thermal plasma density (1-10^5 cm-3) and temperature with up to 0.5 ms and 1 s time resolution, respectively; measurement of the density fluctuations over a dynamic range of 0.1-20 % with a time resolution of at least 1 ms; measurements of time delays between different antennae with time resolution down to 0.03 ms; and wavelength measurements for frequencies up to 20 kHz using on-board interferometric techniques and multiple sensor separations. The FAST electric field instrument stopped providing meaningful data around 2002.
Electro-Static Analyzers (ESA) Sixteen
electrostatic analyzers (ESAs) configured in four stacks are used for both electron and ion measurements. The four stacks are placed around the spacecraft such that the entire package is provided a full 360°
field of view (FoV). The ESAs can provide a 64-step energy sweep, covering approximately 3 eV to 30 KeV up to 16 times per second. Each ESA stack contains three Stepped ESA (SESA) analyzers that are used to make the high-time resolution electron measurements and a single ion or electron spectrometer (IESA or EESA) used to make detailed distribution measurements. The EESA and IESA step through their energy range, collecting 24, 48, or 96 energy samples in 32 pitch angle sectors. The standard mode (24 samples) measures a pitch angle distribution every 78 ms. The other modes allow alternate trade-offs between time and energy resolution. Depending on their operating mode the SESA sensors measure a distribution containing 16 pitch angle bins and 6, 12, 24, or 48 energy bins. The minimum sample time for an array of 6 energies is 1.6 ms. Angular resolution is 11.2° for the EESA/IESA and 22.5° for the SESA.
Time of Flight Energy Angle Mass Spectrograph (TEAMS) The Time-of-flight Energy Angle Mass Spectrograph (TEAMS) instrument is a high-sensitivity mass-resolving spectrometer with an instantaneous 360*8° field of view. It is designed to measure the full three-dimensional distribution function of the major ion species (H+, He++, He+, O+, O2+ plus NO+). The sensor is very similar to the CODIF sensor for the CLUSTER mission and goes back to instruments flown on
AMPTE-IRM (SULEICA, 3D-Plasma Instrument). TEAMS selects the incoming ions according to energy per charge (1.2 eV/e to 12 keV/e) by electrostatic deflection in a toroidal section analyzer with subsequent acceleration (up to 25 keV/e) and
time of flight (ToF) analysis. For each individual ion the instruments measures the energy per charge (electrostatic analyzer) the mass per charge (ToF analyzer), the incidence azimuthal angle (given by spacecraft spin; 5.6° or 11.2° resolution), and the incidence polar angle (given by the sectoring in the ToF unit; 22.5° sectors). Depending on the measurement mode the full energy sweep is performed 32 or 64 times per spin period thus providing a two-dimensional cut through the distribution function in polar angle every 156 ms or 78 ms. One complete three-dimensional ion distribution function is obtained in half a spin period (2.5 seconds). The instrument's axis of symmetry is perpendicular to the spacecraft spin axis and the spacecraft surface. TEAMS operates in a number of different data acquisition modes. The Survey Distribution mode samples H+, O+, He+, and He++ with high angle (64) and energy (48) resolution. Time resolution can be as low as 80 ms (slow survey) and as high as 10 ms (fast survey). High Mass Distribution mode uses a high mass (64) resolution to identify minor species; angle (16) and energy (16) resolution is low in this mode; time resolution varies from 80 ms (slow) to 20 ms (fast). Burst mode provides data for the four major ion species with the highest time (0.08 ms), angle (16), and energy (48) resolution. Additional measurement modes are geared towards the Pole Channels, Monitor Rates, and PHA Events.
Tri-Axial Fluxgate and Search-coil Magnetometers The FAST magnetic field instrumentation includes a DC fluxgate magnetometer and an
Alternating current (AC) search coil magnetometer. The fluxgate magnetometer is a three-axis instrument using highly stable low-noise ring core sensors. It is boom-mounted at from the spacecraft body in a shielded housing. It provides magnetic field information from DC to 100 Hz to a 16-bit
analog-to-digital converter. Time resolution is 2 ms and the sensitivity below 50 Hz close to 1
nT. The search coil magnetometer (also boom-mounted) uses a three-axis sensor system that contains laminated permalloy cores, windings and preamplifiers. The design is based on the
OGO-5 instrument with recent developments implemented on classified projects. The signals are further amplified in the electronics before analog-to-digital conversion. An AC magnetic field measurement is provided over the frequency range 10 Hz to 2.5 kHz with a time resolution of 0.1 ms and a frequency-dependent sensitivity between 10^-8 and 10^-10 nT^2/Hz. == End of mission ==