Kosmos 156's instrumentation consisted of: • Two
vidicon cameras for daytime cloud cover pictures • A high-resolution scanning infrared
radiometer for nighttime and daytime imaging of the Earth and clouds • An array of narrow-angle and wide-angle radiometers covering the 0.3–3 μm, 8–12 μm, and 3–30 μm channels to measure the intensity of radiation reflected from clouds and oceans, the surface temperatures of the Earth and cloud tops, and the total flux of thermal energy from the Earth-atmosphere system into space, respectively If the satellite within the radio contact zone of one of two ground stations, images from each vidicon tube were transmitted directly to the ground. Otherwise, they were recorded on magnetic tape for later transmission. The TV images received by these ground stations were processed and transmitted to the Hydrometeorological Center in Moscow, where they were used in forecasting and analysis and subsequently archived. Kosmos 156 had a significantly lower orbital altitude than its U.S. counterparts, the
ESSA satellites ( vs. . As a result, it could not provide continuous overlapping global coverage despite its cameras having 2.5 times the resolution of those carried on the ESSA satellites. To close coverage gaps, at least two satellites were required in the satellite system. Cloud-cover mosaics were produced from 10 or more individual cloud-cover pictures at the Soviet Hydrometeorological Center to provide a more comprehensive view of global weather systems. Before reaching the thermistor
bolometer, radiation was reflected from the scanning mirror, passed through a stationary modulating disk and filter window onto a parabolic mirror, and finally focused into a parallel beam which passed through a movable modulating disk. The stationary and movable modulating disks provided channel switching, first sending the Earth-atmosphere radiation and then the space radiation to the parabolic mirror and bolometer. The bolometer converted the radiant flux into variable electric voltages (0 to 6 V) whose frequency was equal to the modulator frequency and whose magnitudes were proportional to the differences in the radiant flux intensities between Earth and space developed at the bolometer output. During the movement of the scanning mirror through a ± 40° sector, line scanning (40 lines/min) of the target area was accomplished in a plane normal to the orbital plane using a forward and back path, while scanning along the flight path was provided by the relative motion of the satellite concerning the Earth. In each scan, with the indicated viewing and scanning angles from the satellite's orbital altitude, the radiometer recorded the mean radiation intensities from a band about wide with a resolution of approximately at nadir to approximately at the edges. The radiometer was capable of measuring radiation temperatures within 2–3° for temperatures above 273 K and within 7–8° for temperatures below 273 K. The instrumentation consisted of four radiometers: a pair of scanning, narrow-angle, two-channel radiometers, and a pair of nonscanning, wide-angle, two-channel radiometers. The narrow-angle (4–5° field of view) radiometers measured radiation in all three spectral bands, while the wide-angle (136–140° FOV) radiometers operated only in the 0.3–3 and 3–30 μm bands. In the narrow-angle radiometer, the 0.3–3 μm band was measured in one channel and the 8–12 and 3–30 μm bands were combined in the second channel. In the second channel, the two bands were separated by the exchange of corresponding filters as the radiometer scanned in alternate directions. Earth radiation entered the narrow-angle radiometer through a cylindrical fairing (KRS-5 crystal) and fell onto a conical scanning mirror. The radiation was reflected from the mirror through a three-lobed rotating mirror chopper that modulated the radiation flux at a frequency of 80 Hz. The chopper alternately reflected Earth radiation and space radiation, which entered through a separate KRS-5 crystal window, onto one of three openings in a colour filter wheel – one filter for each spectral band. The particular spectral band that passed through then fell on an off-axis parabolic mirror that focused the radiation flux onto a bolometric receiver. Periodic calibration was made when the scanning mirror moved to a 90° angle from nadir with simultaneous turning on and viewing of a silicon standard lamp. The 0.3–3 μm channel did not use the two-beam system nor filter switching. The output from the modulated flow of radiation on the bolometer was amplified, rectified, filtered, and fed into the radio-telemetry system over eight channels. The wide-angle radiometers had identical optical systems for both channels. The Earth radiation entered the radiometer through a hemispherical shell composed of quartz or KRS-5 crystal with a coating that determined the passband. The radiation was then modulated with a frequency of 64 Hz and fell on a bolometric receiver. As in the narrow-angle radiometers, the bolometer output was processed and fed into the radio-telemetry system. The wide-angle radiometer was standardized simultaneously with the narrow-angle radiometer by the input of a standard 64 Hz calibrating frequency into the amplification circuit. The relative
root mean square measuring error for both types of radiometers was approximately 0.5%. To provide backup capability, one wide-angle and one narrow-angle radiometer were held in reserve and could be activated from the ground. The orientation of the satellite was maintained by the motion of the satellite relative to the Earth, which ensured that the primary optical axes of the radiometers were oriented vertically downward toward the survey of the Earth's surface. The narrow-angle radiometer scanned 66° to either side of nadir in a plane normal to the orbital plane by rocking the scanning mirror about the optical axis. The radiometers covered a strip about wide on the Earth's surface and had a ground resolution of at nadir. The data were reduced at the ground stations and were transmitted in binary form to the Hydrometeorological Center, where they were recorded in digital form on magnetic tape and were used to produce various analysis products such as Earth-atmosphere albedo charts and radiation temperature maps. The data were archived at the Hydrometeorological Center. ==Mission==