LAMP is less versatile than PCR, the most well-established nucleic acid amplification technique. LAMP is useful primarily as a diagnostic or detection technique, but is not useful for cloning or many other molecular biology applications enabled by PCR. Because LAMP uses 4 (or 6) primers targeting 6 (or 8) regions within a fairly small segment of the genome, and because primer design is subject to numerous constraints, it is difficult to design primer sets for LAMP "by eye". Free, open-source or commercial software packages are generally used to assist with LAMP primer design, although the primer design constraints mean there is less freedom to choose the target site than with PCR. In a diagnostic application, this must be balanced against the need to choose an appropriate target (e.g., a conserved site in a highly variable viral genome, or a target that is specific for a particular strain of pathogen). Multiple degenerated sequences may be required to cover the different variant strains of the same species. A consequence of having such a cocktail of primers can be non-specific amplification in the late amplification. Multiplexing approaches for LAMP are less developed than for PCR. The larger number of primers per target in LAMP increases the likelihood of primer-primer interactions for multiplexed target sets. The product of LAMP is a series of concatemers of the target region, giving rise to a characteristic "ladder" or banding pattern on a gel, rather than a single band as with PCR. Although this is not a problem when detecting single targets with LAMP, "traditional" (endpoint) multiplex PCR applications wherein identity of a target is confirmed by size of a band on a gel are not feasible with LAMP. Multiplexing in LAMP has been achieved by choosing a target region with a restriction site, and digesting prior to running on a gel, such that each product gives rise to a distinct size of fragment, although this approach adds complexity to the experimental design and protocol. The use of a strand-displacing DNA polymerase in LAMP also precludes the use of hydrolysis probes, e.g.
TaqMan probes, which rely upon the 5'-3'
exonuclease activity of
Taq polymerase. An alternative real-time multiplexing approach based on fluorescence quenchers has been reported. SYBR green dye may be added to view LAMP in real-time. However, in the late amplification, primer-dimer amplification may contribute to a false positive signal. The use of
inorganic pyrophosphatase in a SYBR reaction mix allows the use of melt analysis to distinguish correct amplification Although different mitigation strategies have been proposed for false-positive results in assays based on this method, nonspecific amplification due to various factors including the absence of temperature gating mechanisms is one of the major limitations of Loop-mediated isothermal amplification. Lastly, because LAMP requires maintained, elevated incubation temperatures (60–65 °C), some sort of heating mechanism, thermostat, and/or insulator is required (though not necessarily a thermal cycler). This requirement makes LAMP less ideally suited for in the field, point-of-care diagnostics which would ideally function at ambient temperature. == Research ==