Machine body The first CMM was developed by the
Ferranti Company of Scotland in the 1950s as the result of a direct need to measure precision components in their military products, although this machine only had 2 axes. The first 3-axis models began appearing in the 1960s (made by DEA of Italy and LK of the UK), and computer control debuted in the early 1970s, but the first working CMM was developed and put on sale by Browne & Sharpe in Melbourne, England. Leitz Germany subsequently produced a fixed machine structure with moving table. In modern machines, the gantry-type superstructure has two legs and is often called a bridge. This moves freely along the granite table with one leg (often referred to as the inside leg) following a guide rail attached to one side of the granite table. The opposite leg (often outside leg) simply rests on the granite table following the vertical surface contour.
Air bearings are the chosen method for ensuring friction-free travel. In these, compressed air is forced through a series of very small holes in a flat bearing surface to provide a smooth-but-controlled air cushion on which the CMM can move in a nearly frictionless manner which can be compensated for through software. The movement of the bridge or gantry along the granite table forms one axis of the XY plane. The bridge of the gantry contains a carriage which traverses between the inside and outside legs and forms the other horizontal axis. The third axis of movement (Z axis) is provided by the addition of a vertical quill or spindle which moves up and down through the center of the carriage. The touch probe forms the sensing device on the end of the quill. The movement of the X, Y, and Z axes fully describes the measuring envelope. Optional rotary tables can be used to enhance the approachability of the measuring probe to complicated workpieces. The rotary table as a fourth drive axis does not enhance the measuring dimensions, which remain 3D, but it does provide a degree of flexibility. Some touch probes are themselves powered rotary devices with the probe tip able to swivel vertically through more than 180° and through a full 360° rotation. CMMs are now also available in a variety of other forms. These include CMM arms that use angular measurements taken at the joints of the arm to calculate the position of the stylus tip, and can be outfitted with probes for laser scanning and optical imaging. Such arm CMMs are often used where their portability is an advantage over traditional fixed-bed CMMs: by storing measured locations, programming software also allows moving the measuring arm itself, and its measurement volume, around the part to be measured during a measurement routine. Because CMM arms imitate the flexibility of a human arm, they are also often able to reach the insides of complex parts that could not be probed using a standard three axis machine.
Mechanical probe In the early days of coordinate measurement, mechanical probes were fitted into a special holder on the end of the quill. A very common probe was made by soldering a hard ball to the end of a shaft. This was ideal for measuring a whole range of flat-face, cylindrical, or spherical surfaces. Other probes were ground to specific shapes, for example a quadrant, to enable measurement of special features. These probes were physically held against the workpiece with the position in space being read from a 3-axis digital readout (DRO) or, in more advanced systems, being logged into a computer by means of a footswitch or similar device. Measurements taken by this contact method were often unreliable as machines were moved by hand and each machine operator applied different amounts of pressure on the probe or adopted differing techniques for the measurement. A further development was the addition of motors for driving each axis. Operators no longer had to physically touch the machine but could drive each axis using a handbox with joysticks in much the same way as with modern remote controlled cars. Measurement
accuracy and precision improved dramatically with the invention of the electronic touch trigger probe. The pioneer of this new probe device was
David McMurtry who subsequently formed what is now
Renishaw plc. Although still a contact device, the probe had a spring-loaded steel ball (later ruby ball) stylus. As the probe touched the surface of the component, the stylus deflected and simultaneously sent the X,Y,Z coordinate information to the computer. Measurement errors caused by individual operators became fewer, and the stage was set for the introduction of CNC operations and the coming of age of CMMs. Optical probes are lens-and-CCD systems, which are moved like the mechanical ones, and are aimed at the point of interest, instead of touching the material. The captured image of the surface will be enclosed in the borders of a measuring window, until the residue is adequate to contrast between black and white zones. The dividing curve can be calculated to a point, which is the wanted measuring point in space. The horizontal information on the CCD is 2D (XY) and the vertical position is the position of the complete probing system on the stand Z-drive (or other device component).
Scanning probe systems There are newer models that have probes that drag along the surface of the part while taking points at specified intervals, known as scanning probes. This method of CMM inspection is often more accurate than the conventional touch-probe method and most times faster as well. The next generation of scanning, known as noncontact scanning, which includes high speed laser single point triangulation, laser line scanning, and white light scanning, is advancing very quickly. This method uses either laser beams or white light that are projected against the surface of the part. Many thousands of points can then be taken and used not only to check size and position, but to create a 3D image of the part as well. This "
point-cloud data" can then be transferred to CAD software to create a working 3D model of the part. These optical scanners are often used on soft or delicate parts or to facilitate
reverse engineering. ;Micrometrology probes Probing systems for microscale metrology applications are another emerging area. There are several commercially available coordinate measuring machines that have a microprobe integrated into the system, several specialty systems at government laboratories, and any number of university-built metrology platforms for microscale metrology. Although these machines are good and in many cases excellent metrology platforms with nanometric scales, their primary limitation is a reliable, robust, capable micro/nano probe. Challenges for microscale probing technologies include the need for a high-aspect-ratio probe giving the ability to access deep, narrow features with low contact forces so as to not damage the surface and high precision (nanometer level). Additionally, microscale probes are susceptible to environmental conditions such as
humidity and surface interactions such as stiction (caused by
adhesion, meniscus, and/or
Van der Waals forces among others). Technologies to achieve microscale probing include scaled-down version of classical CMM probes, optical probes, and a
standing wave probe, among others. However, current optical technologies cannot be scaled small enough to measure deep, narrow features, and optical resolution is limited by the wavelength of light. X-ray imaging provides a picture of the feature but no traceable metrology information. ;Physical principles Optical probes and laser probes can be used (if possible in combination), which change CMMs to measuring microscopes or multi-sensor measuring machines. Fringe projection systems,
theodolite triangulation systems, and laser distance and triangulation systems are not called measuring machines, but the measuring result is the same: a space point. Laser probes are used to detect the distance between the surface and the reference point on the end of the kinematic chain (that is, the end of the Z-drive component). This can use an interferometrical function,
focus variation, light deflection, or a beam-shadowing principle. ==Portable coordinate-measuring machines==