Treatment varies depending on the cause of respiratory arrest. In many cases, it is necessary to establish an alternate airway and providing
artificial ventilation that can include
modes of mechanical ventilation. There are many ways to provide an airway and to deliver breathing support. The list below includes several options.
Opioid-overdose Opioid overdose remains a major cause of death with an increase in rate of death by 12% in the United States from 2016 to 2017. In cases of overdose leading to respiratory arrest, the recommended treatment according to the 2015
American Heart Association guidelines is to administer intramuscular or intranasal
naloxone at an initial dose of 0.04-0.4 mg. Dosing may be repeated up to 2 mg if initial dose is ineffective. Special consideration must be taken in individuals with opioid dependency as naloxone administration can induce severe opioid withdrawal, hence the recommended starting doses above. Goal of naloxone therapy is to restore respiratory drive in the individual, however mechanical ventilation may still be necessary during initial resuscitation.
Bag-valve-mask (BVM) ventilation devices Resistance to
bag valve mask may suggest presence of a foreign body that is obstructing airways and commonly used as a diagnostic tool and treatment for respiratory arrest. The bag-valve-mask device has a self-inflating bag with a soft mask that rests on the face. When the bag is connected to an oxygen supply, the patient will receive 60 to 100% of inspired oxygen. The purpose of bag-valve-mask is to provide adequate temporary ventilation and allow the body to achieve airway control by itself. However, if the bag-valve-mask is left on for more than five minutes, air may be introduced into the stomach. At that point, a nasogastric tube should be inserted to take the accumulated air out. During this process, practitioners must carefully position and maneuver the bag-valve-mask in order to keep airways open. To ensure an adequate seal when using the bag valve mask to ventilate, specific hand positioning is typically used. The provider places his or her thumb and index finger in a 'C' shape on top of the mask and grips the jaw under the mask with the other three fingers, creating an 'E' shape. The thumb and index finger provide downward pressure on the mask while the remaining fingers maintain head tilt and jaw thrust. The free hand can then be used to provide ventilation via the bag. For children, pediatric bags can be used. Pediatric bags have a valve that limits peak airway pressures to around 35–40 cm of water. Practitioners must tweak valve settings to accurately determine each of their patients to avoid hypoventilation or hyperventilation. When applying ventilation with the bag valve mask, the provider should apply just enough pressure to bag to see a chest rise. The rate of manual ventilation should not exceed 12 times per minute, or one ventilation every 5 seconds as to avoid hyperventilation.
Surgical airway Surgical entry is required when the upper airway is obstructed by a foreign body, massive trauma has occurred, or if ventilation cannot be accomplished by any of the aforementioned methods. The requirement of the surgical airway is commonly known as the response to failed intubation. In comparison, surgical airways require 100 seconds to complete from incision to ventilation compared to laryngeal mask airways and other devices. During emergency
cricothyrotomy, the patient lies on his back with neck extended and shoulders backward. The larynx is held in one hand by the practitioner while the other hand is holding a blade to incise the skin through the subcutaneous tissue and into the midline of the cricothyroid membrane to access the trachea. A hollow tube is used inserted into the trachea to keep the airway open. A tracheal hook is used to keep the space open and prevent retraction. Complications may include hemorrhage, subcutaneous emphysema, pneumomediastinum, and pneumothorax. Cricothyrotomy is used as emergency surgical access due to being fast and simple. Another surgical airway method is called
tracheostomy. Tracheostomy is done in the operating room by a surgeon. This is the preferred method for patients requiring long-term ventilation. Tracheostomy uses skin puncture and dilators to insert the tracheostomy tube.
Drugs to aid intubation Patients with respiratory arrest can be intubated without drugs. However, patients can be given sedating and paralytic drugs to minimize discomfort and help out with intubation. Pretreatment includes 100% oxygen, lidocaine, and atropine. 100% oxygen should be administered for 3 to 5 minutes. The time depends on pulse rate, pulmonary function, RBC count, and other metabolic factors.
Lidocaine can be given in 1.5 mg/kg IV a few minutes before sedation and paralysis. The purpose of administering lidocaine is to blunt the sympathetic response of an increased heart rate, blood pressure, and intracranial pressure caused by laryngoscopy. Atropine can be given when children produce a vagal response, evidenced by bradycardia, in response to intubation. Some physicians even give out
vecuronium, which is a neuromuscular blocker to prevent muscle fasciculations in patients over 4 years old. Fasciculations may result in muscle pain on awakening. Laryngoscopy and intubation are uncomfortable procedures, so etomidate may be delivered.
Etomidate is a short-acting IV drug with sedative analgesic properties. The drug works well and does not cause cardiovascular depression. Ketamine is an anesthetic that may be used as well, but it may cause hallucinations or bizarre behavior upon awakening. Thiopental and methohexital may be used as well to provide sedation, but they tend to cause hypotension.
Volume-cycled ventilation The purpose of mechanical ventilators is to deliver a constant volume, constant pressure, or a combination of both with each breath. Any given volume will correspond to a specific pressure on the pressure-volume curve and vice versa in any case. Settings on each mechanical ventilator may include respiratory rate, tidal volume, trigger sensitivity, flow rate, waveform, and inspiratory/expiratory ratio. The volume-cycled ventilation includes the volume-control function and delivers a set tidal volume. The pressure is not a fixed number but it varies with resistance and
capacitance of the respiratory system. The volume-cycled ventilation is the simplest and most efficient of providing ventilation to a patient's airway compared to other methods of mechanical ventilation. Each inspiratory effort that is beyond the set sensitivity threshold will be accounted for and fixed to the delivery of the corresponding tidal volume. If the patient does not breathe enough, then the volume-cycled ventilation will initiate a breath for the patient to bring up the breathing rate to the minimum respiratory rate. The synchronized intermittent mandatory ventilation (SIMV) is a similar method of mechanical ventilation that also delivers breaths at a fixed rate and volume that corresponds to the patient's breathing. Unlike the Volume-Cycled Ventilation, patient efforts above the fixed rate are unassisted in the synchronized intermittent mandatory ventilation (SIMV).
Pressure-cycled ventilation The pressure-cycled ventilation includes pressure control ventilation and pressure support ventilation. Both methods offer a set inspiratory pressure. The
tidal volume varies depending on the resistance and elastance of the respiratory system. Pressure-cycled ventilation can help alleviate symptoms in patients with
acute respiratory distress syndrome by limiting the distending pressure of the lungs. The pressure control ventilation is specifically a pressure-cycled form of assist-control ventilators. Assist-control ventilators describe a mode of ventilation that maintains a minimum respiratory rate regardless of whether or not the patient initiates a spontaneous breath. Each inspiratory effort that is beyond the sensitivity threshold delivers full pressures support for a fixed inspiratory time. There is maintenance of a minimum respiratory rate. In the pressure support ventilation, the minimum rate is not set. Instead, all breaths are triggered by the patient. The way that the pressure support ventilation works is by assisting the patient with a constant pressure until the patient's inspiratory flow falls below a threshold. The longer, deeper inspiratory flows by the patient will result in a larger tidal volume. This method of mechanical ventilation will help patients assume more work of breathing.
Noninvasive positive pressure ventilation (NIPPV) Noninvasive positive pressure ventilation is the delivery of positive pressure ventilation through a tight-fitting mask that covers the nose and mouth. It assists patients who can spontaneously breathe. Noninvasive positive pressure ventilation delivers end-expiratory pressure with a volume control setting. There are two ways that noninvasive positive pressure ventilation can be delivered: continuous
positive airway pressure or bilevel positive airway pressure. In continuous positive airway pressure, constant pressure is maintained throughout cycles of respiration with no additional inspiratory support. In bilevel positive airway pressure, both expiratory positive airway pressure and inspiratory positive airway pressure are set by the physician. Noninvasive positive pressure ventilation should not be administered to people who are hemodynamically unstable, gastric emptying impaired, bowel obstructed or pregnant. In these circumstances, swallowing large amounts of air will result in vomiting and possibly death. If frequent arrhythmias, myocardial ischemia and shock arrhythmias occur, practitioners should change delivery to endotracheal intubation or conventional mechanical ventilation. People who should not use noninvasive positive pressure ventilation include
obtunded patients or ones with secretions. Noninvasive positive pressure ventilation can be used in an outpatient setting for patients with obstructive sleep apnea. ==See also==