In RT-PCR, the
RNA template is first converted into a
complementary DNA (cDNA) using a
reverse transcriptase (RT). The cDNA is then used as a template for exponential amplification using PCR. The use of RT-PCR for the detection of RNA transcript has revolutionized the study of gene expression in the following important ways: • Made it theoretically possible to detect the transcripts of practically any gene • Enabled sample amplification and eliminated the need for abundant starting material required when using northern blot analysis • Provided tolerance for RNA degradation as long as the RNA spanning the primer is intact On the other hand, the entire reaction from cDNA synthesis to PCR amplification occurs in a single tube in the one-step approach. The one-step approach is thought to minimize experimental variation by containing all of the enzymatic reactions in a single environment. It eliminates the steps of pipetting cDNA product, which is labor-intensive and prone to contamination, to PCR reaction. The further use of inhibitor-tolerant
thermostable DNA polymerases, polymerase enhancers with an optimized one-step RT-PCR condition, supports the reverse transcription of the RNA from unpurified or crude samples, such as
whole blood and
serum. However, the starting RNA templates are prone to degradation in the one-step approach, and the use of this approach is not recommended when repeated assays from the same sample is required. Additionally, the one-step approach is reported to be less accurate compared to the two-step approach. It is also the preferred method of analysis when using DNA binding dyes such as
SYBR Green since the elimination of
primer-dimers can be achieved through a simple change in the
melting temperature. Nevertheless, the one-step approach is a relatively convenient solution for the rapid detection of target RNA directly in biosensing.
End-point RT-PCR vs real-time RT-PCR Quantification of RT-PCR products can largely be divided into two categories: end-point and real-time. The use of end-point RT-PCR is preferred for measuring gene expression changes in small number of samples, but the real-time RT-PCR has become the gold standard method for validating quantitative results obtained from array analyses or gene expression changes on a global scale.
End-point RT-PCR The measurement approaches of end-point RT-PCR requires the detection of gene expression levels by the use of fluorescent dyes like
ethidium bromide,
P32 labeling of PCR products using
phosphorimager, or by
scintillation counting. ; Relative RT-PCR: Relative quantifications of RT-PCR involves the co-amplification of an internal control simultaneously with the gene of interest. The internal control is used to normalize the samples. Once normalized, a direct comparison of relative transcript abundances across multiple samples of mRNA can be made. One precaution to note is that the internal control must be chosen so that it is not affected by the experimental treatment. The expression level should be constant across all samples and with the mRNA of interest for the results to be accurate and meaningful. Because the quantification of the results are analyzed by comparing the linear range of the target and control amplification, it is crucial to take into consideration the starting target molecules concentration and their amplification rate prior to starting the analysis. The results of the analysis are expressed as the ratios of gene signal to internal control signal, which the values can then be used for the comparison between the samples in the estimation of relative target RNA expression. ; Competitive RT-PCR: Competitive RT-PCR technique is used for absolute quantification. It involves the use of a synthetic “competitor” RNA that can be distinguished from the target RNA by a small difference in size or sequence. It is important for the design of the synthetic RNA be identical in sequence but slightly shorter than the target RNA for accurate results. Once designed and synthesized, a known amount of the competitor RNA is added to experimental samples and is co-amplified with the target using RT-PCR. Then, a concentration curve of the competitor RNA is produced and it is used to compare the RT-PCR signals produced from the endogenous transcripts to determine the amount of target present in the sample. ; Comparative RT-PCR: Comparative RT-PCR is similar to the competitive RT-PCR in that the target RNA competes for amplification reagents within a single reaction with an internal standard of unrelated sequence. Once the reaction is complete, the results are compared to an external standard curve to determine the target RNA concentration. In comparison to the relative and competitive quantification methods, comparative RT-PCR is considered to be the more convenient method to use since it does not require the investigator to perform a pilot experiment; in relative RT-PCR, the exponential amplification range of the mRNA must be predetermined and in competitive RT-PCR, a synthetic competitor RNA must be synthesized.
Real-time RT-PCR The emergence of novel fluorescent DNA labeling techniques in the past few years has enabled the analysis and detection of PCR products in real-time and has consequently led to the widespread adoption of real-time RT-PCR for the analysis of gene expression. Not only is real-time RT-PCR now the method of choice for quantification of gene expression, it is also the preferred method of obtaining results from
array analyses and gene expressions on a global scale. Currently, there are four different fluorescent DNA
probes available for the real-time RT-PCR detection of PCR products:
SYBR Green,
TaqMan,
molecular beacons, and
scorpion probes. All of these probes allow the detection of PCR products by generating a fluorescent signal. While the SYBR Green dye emits its fluorescent signal simply by binding to the double-stranded DNA in solution, the TaqMan probes', molecular beacons' and scorpions' generation of fluorescence depend on
Förster Resonance Energy Transfer (FRET) coupling of the dye molecule and a quencher moiety to the oligonucleotide substrates. ;
SYBR Green: When the SYBR Green binds to the double-stranded DNA of the PCR products, it will emit light upon excitation. The intensity of the fluorescence increases as the PCR products accumulate. This technique is easy to use since designing of probes is not necessary given lack of specificity of its binding. However, since the dye does not discriminate the double-stranded DNA from the PCR products and those from the primer-dimers, overestimation of the target concentration is a common problem. Where accurate quantification is an absolute necessity, further assay for the validation of results must be performed. Nevertheless, among the real-time RT-PCR product detection methods, SYBR Green is the most economical and easiest to use. Additionally, these probes are light sensitive and must be carefully frozen as aliquots to prevent degradation. ;
Molecular beacon probes: Similar to the TaqMan probes, molecular beacons also make use of FRET detection with fluorescent probes attached to the 5' end and a quencher attached to the 3' end of an oligonucleotide substrate. However, whereas the TaqMan fluorescent probes are cleaved during amplification, molecular beacon probes remain intact and rebind to a new target during each reaction cycle. When free in solution, the close proximity of the fluorescent probe and the quencher molecule prevents fluorescence through FRET. However, when molecular beacon probes hybridize to a target, the fluorescent dye and the quencher are separated resulting in the emittance of light upon excitation. As is with the TaqMan probes, molecular beacons are expensive to synthesize and require separate probes for each RNA target. ; Multiplex probes: TaqMan probes, molecular beacons, and scorpions allow the concurrent measurement of PCR products in a single tube. This is possible because each of the different fluorescent dyes can be associated with a specific emission spectra. Not only does the use of multiplex probes save time and effort without compromising test utility, its application in wide areas of research such as gene deletion analysis, mutation and polymorphism analysis, quantitative analysis, and RNA detection, make it an invaluable technique for laboratories of many discipline. Two strategies are commonly employed to quantify the results obtained by real-time RT-PCR; the standard curve method and the comparative threshold method. == Application ==