• Tongue Larssen - Tongue Larssens are up to 34 meters long and 80 centimeters wide. They have locks, which allow people to connect one profile to another vertically to create a sealed metal diaphragm wall. Transverse profiles can be in the shape of letters: S, Z, L or Ω (
Omega) where the trough can be of varying depth. • Special Profile - Special profiles are long and narrow without locks. They usually have a wavy or trough shape to increase the resistance to bending. • Cantilever - Bending moments and shears are calculated under the assumption that the wall is a
cantilever beam fixed at the bottom of the wall. • Anchored Wall Design- Bending moments, shears, and anchor force are calculated under the assumption that the wall is a beam with simple supports at the anchor elevation and at the bottom of the wall (the place where the wall moves beneath the surface of the ground. With the bottom of the wall at the penetration consistent with a
factor of safety of 1, the lateral reaction at the bottom support will be zero and the lateral reaction at the upper support will be the horizontal component of the anchor force. ==Applications==