Steady-state conduction Steady-state conduction is the form of conduction that happens when the temperature difference(s) driving the conduction are constant, so that (after an equilibration time), the spatial distribution of temperatures (temperature field) in the conducting object does not change any further. Thus, all partial derivatives of temperature
concerning space may either be zero or have nonzero values, but all derivatives of temperature at any point
concerning time are uniformly zero. In steady-state conduction, the amount of heat entering any region of an object is equal to the amount of heat coming out (if this were not so, the temperature would be rising or falling, as thermal energy was tapped or trapped in a region). For example, a bar may be cold at one end and hot at the other, but after a state of steady-state conduction is reached, the
spatial gradient of temperatures along the bar does not change any further, as time proceeds. Instead, the temperature remains constant at any given cross-section of the rod normal to the direction of heat transfer, and this temperature varies linearly in space in the case where there is no heat generation in the rod. In steady-state conduction, all the laws of direct current electrical conduction can be applied to "heat currents". In such cases, it is possible to take "thermal resistances" as the analog to
electrical resistances. In such cases, temperature plays the role of voltage, and heat transferred per unit time (heat power) is the analog of electric current. Steady-state systems can be modeled by networks of such thermal resistances in series and parallel, in exact analogy to electrical networks of resistors. See
purely resistive thermal circuits for an example of such a network.
Transient conduction During any period in which temperatures changes
in time at any place within an object, the mode of thermal energy flow is termed
transient conduction. Another term is "non-steady-state" conduction, referring to the time-dependence of temperature fields in an object. Non-steady-state situations appear after an imposed change in temperature at a boundary of an object. They may also occur with temperature changes inside an object, as a result of a new source or sink of heat suddenly introduced within an object, causing temperatures near the source or sink to change in time. When a new perturbation of temperature of this type happens, temperatures within the system change in time toward a new equilibrium with the new conditions, provided that these do not change. After equilibrium, heat flow into the system once again equals the heat flow out, and temperatures at each point inside the system no longer change. Once this happens, transient conduction is ended, although steady-state conduction may continue if heat flow continues. If changes in external temperatures or internal heat generation changes are too rapid for the equilibrium of temperatures in space to take place, then the system never reaches a state of unchanging temperature distribution in time, and the system remains in a transient state. An example of a new source of heat "turning on" within an object, causing transient conduction, is an engine starting in an automobile. In this case, the transient thermal conduction phase for the entire machine is over, and the steady-state phase appears, as soon as the engine reaches steady-state
operating temperature. In this state of steady-state equilibrium, temperatures vary greatly from the engine cylinders to other parts of the automobile, but at no point in space within the automobile does temperature increase or decrease. After establishing this state, the transient conduction phase of heat transfer is over. New external conditions also cause this process: for example, the copper bar in the example steady-state conduction experiences transient conduction as soon as one end is subjected to a different temperature from the other. Over time, the field of temperatures inside the bar reaches a new steady-state, in which a constant temperature gradient along the bar is finally set up, and this gradient then stays constant in time. Typically, such a new steady-state gradient is approached exponentially with time after a new temperature-or-heat source or sink, has been introduced. When a "transient conduction" phase is over, heat flow may continue at high power, so long as temperatures do not change. An example of transient conduction that does not end with steady-state conduction, but rather no conduction, occurs when a hot copper ball is dropped into oil at a low temperature. Here, the temperature field within the object begins to change as a function of time, as the heat is removed from the metal, and the interest lies in analyzing this spatial change of temperature within the object over time until all gradients disappear entirely (the ball has reached the same temperature as the oil). Mathematically, this condition is also approached exponentially; in theory, it takes infinite time, but in practice, it is over, for all intents and purposes, in a much shorter period. At the end of this process with no heat sink but the internal parts of the ball (which are finite), there is no steady-state heat conduction to reach. Such a state never occurs in this situation, but rather the end of the process is when there is no heat conduction at all. The analysis of non-steady-state conduction systems is more complex than that of steady-state systems. If the conducting body has a simple shape, then exact analytical mathematical expressions and solutions may be possible (see
heat equation for the analytical approach). However, most often, because of complicated shapes with varying
thermal conductivities within the shape (i.e., most complex objects, mechanisms or machines in engineering) often the application of approximate theories is required, and/or
numerical analysis by computer. One popular graphical method involves the use of
Heisler Charts. Occasionally, transient conduction problems may be considerably simplified if regions of the object being heated or cooled can be identified, for which
thermal conductivity is very much greater than that for heat paths leading into the region. In this case, the region with high conductivity can often be treated in the
lumped capacitance model, as a "lump" of material with a simple thermal capacitance consisting of its aggregate
heat capacity. Such regions warm or cool, but show no significant temperature
variation across their extent, during the process (as compared to the rest of the system). This is due to their far higher conductance. During transient conduction, therefore, the temperature across their conductive regions changes uniformly in space, and as a simple exponential in time. An example of such systems is those that follow
Newton's law of cooling during transient cooling (or the reverse during heating). The equivalent thermal circuit consists of a simple capacitor in series with a resistor. In such cases, the remainder of the system with a high thermal resistance (comparatively low conductivity) plays the role of the resistor in the circuit.
Relativistic conduction The theory of
relativistic heat conduction is a model that is compatible with the theory of
special relativity. For most of the last century, it was recognized that the Fourier equation is in contradiction with the theory of relativity because it admits an infinite speed of propagation of heat signals. For example, according to the Fourier equation, a pulse of heat at the origin would be felt at infinity instantaneously. The speed of information propagation is faster than the
speed of light in vacuum, which is physically inadmissible within the framework of relativity.
Quantum conduction Second sound is a
quantum mechanical phenomenon in which
heat transfer occurs by
wave-like motion, rather than by the more usual mechanism of
diffusion. Heat takes the place of pressure in normal sound waves. This leads to a very high
thermal conductivity. It is known as "second sound" because the wave motion of heat is similar to the propagation of sound in air. This is called quantum conduction. == Fourier's law ==