The displaced dispatchable generation could be coal, natural gas, biomass, nuclear, geothermal or storage hydro. Rather than starting and stopping nuclear or geothermal, it is cheaper to use them as constant
base load power. Any power generated in excess of demand can displace heating fuels, be converted to storage or sold to another grid. Biofuels and conventional hydro can be saved for later when intermittents are not generating power. Some forecast that “near-firm” renewables (batteries with solar and/or wind) power will be cheaper than existing nuclear by the late 2020s: therefore they say base load power will not be needed.
Alternatives to burning coal and natural gas which produce fewer
greenhouse gases may eventually make fossil fuels a
stranded asset that is left in the ground. Highly integrated grids favor flexibility and performance over cost, resulting in more plants that operate for fewer hours and lower
capacity factors. All sources of electrical power have some degree of variability, as do demand patterns which routinely drive large swings in the amount of electricity that suppliers feed into the grid. Wherever possible, grid operations procedure are designed to match supply with demand at high levels of reliability, and the tools to influence supply and demand are well-developed. The introduction of large amounts of highly variable power generation may require changes to existing procedures and additional investments. The capacity of a reliable
renewable power supply, can be fulfilled by the use of
backup or extra infrastructure and technology, using mixed renewables to produce electricity
above the intermittent average, which may be used to meet regular and unanticipated supply demands. Additionally, the storage of energy to fill the shortfall intermittency or for emergencies can be part of a reliable power supply. In practice, as the power output from wind varies, partially loaded conventional plants, which are already present to provide response and reserve, adjust their output to compensate. While low penetrations of intermittent power may use existing levels of response and spinning reserve, the larger overall variations at higher penetrations levels will require additional reserves or other means of compensation.
Operational reserve All managed grids already have existing operational and "spinning" reserve to compensate for existing uncertainties in the power grid. The addition of intermittent resources such as wind does not require 100% "back-up" because operating reserves and balancing requirements are calculated on a system-wide basis, and not dedicated to a specific generating plant. Some gas, or hydro power plants are partially loaded and then controlled to change as demand changes or to replace rapidly lost generation. The ability to change as demand changes is termed "response". The ability to quickly replace lost generation, typically within timescales of 30 seconds to 30 minutes, is termed "spinning reserve". Generally thermal plants running as
peaking plants will be less efficient than if they were running as
base load. Hydroelectric facilities with storage capacity, such as the traditional dam configuration, may be operated as base load or peaking plants. Grids can contract for
grid battery plants, which provide immediately available power for an hour or so, which gives time for other generators to be started up in the event of a failure, and greatly reduces the amount of spinning reserve required.
Demand response Demand response is a change in consumption of energy to better align with supply. It can take the form of switching off loads, or absorb additional energy to correct supply/demand imbalances. Incentives have been widely created in the American, British and French systems for the use of these systems, such as favorable rates or capital cost assistance, encouraging consumers with large loads to take them offline whenever there is a shortage of capacity, or conversely to increase load when there is a surplus. Certain types of load control allow the power company to turn loads off remotely if insufficient power is available. In France large users such as CERN cut power usage as required by the System Operator - EDF under the encouragement of the EJP tariff.
Energy demand management refers to incentives to adjust use of electricity, such as higher rates during peak hours. Real-time variable electricity pricing can encourage users to adjust usage to take advantage of periods when power is cheaply available and avoid periods when it is more scarce and expensive. Some loads such as desalination plants, electric boilers and industrial refrigeration units, are able to store their output (water and heat). Several papers also concluded that
Bitcoin mining loads would reduce
curtailment,
hedge electricity price risk, stabilize the grid, increase the
profitability of renewable energy power stations and therefore accelerate
transition to sustainable energy. But others argue that Bitcoin mining can never be sustainable. Instantaneous demand reduction. Most large systems also have a category of loads which instantly disconnect when there is a generation shortage, under some mutually beneficial contract. This can give instant load reductions or increases.
Storage so that output can be provided after the sun goes down, and output can be scheduled to meet demand requirements. The 280 MW
Solana Generating Station is designed to provide six hours of energy storage. This allows the plant to generate about 38 percent of its rated capacity over the course of a year. of lithium-ion batteries: the price of batteries declined by 97% in three decades. At times of low load where non-dispatchable output from wind and solar may be high, grid stability requires lowering the output of various dispatchable generating sources or even increasing controllable loads, possibly by using energy storage to time-shift output to times of higher demand. Such mechanisms can include:
Pumped storage hydropower is the most prevalent existing technology used, and can substantially improve the economics of wind power. The availability of hydropower sites suitable for storage will vary from grid to grid. Typical round trip efficiency is 80%. Traditional lithium-ion is the most common type used for grid-scale battery storage . Rechargeable
flow batteries can serve as a large capacity, rapid-response storage medium.
Flywheel energy storage systems have some advantages over chemical batteries. Along with substantial durability which allows them to be cycled frequently without noticeable life reduction, they also have very fast response and ramp rates. They can go from full discharge to full charge within a few seconds. They can be manufactured using non-toxic and environmentally friendly materials, easily recyclable once the service life is over.
Thermal energy storage stores heat. Stored heat can be used directly for heating needs or converted into electricity. In the context of a CHP plant a heat storage can serve as a functional electricity storage at comparably low costs.
Ice storage air conditioning Ice can be stored inter seasonally and can be used as a source of air-conditioning during periods of high demand. Present systems only need to store ice for a few hours but are well developed. Storage of electrical energy results in some lost energy because storage and retrieval are not perfectly efficient. Storage also requires capital investment and space for storage facilities.
Geographic diversity and complementing technologies The variability of production from a single wind turbine can be high. Combining any additional number of turbines, for example, in a wind farm, results in lower statistical variation, as long as the
correlation between the output of each turbine is imperfect, and the correlations are always imperfect due to the distance between each turbine. Similarly, geographically distant wind turbines or wind farms have lower correlations, reducing overall variability. Since wind power is dependent on weather systems, there is a limit to the benefit of this geographic diversity for any power system. Multiple wind farms spread over a wide geographic area and gridded together produce power more constantly and with less variability than smaller installations.
Wind output can be predicted with some degree of confidence using weather forecasts, especially from large numbers of turbines/farms. The ability to predict wind output is expected to increase over time as data is collected, especially from newer facilities. Besides, wind energy has often a peak in the winter season, whereas solar energy has a peak in the summer season; the combination of wind and solar reduces the need for dispatchable backup power. • In some locations, electricity demand may have a high correlation with wind output, particularly in locations where cold temperatures drive electric consumption, as cold air is denser and carries more energy. • The allowable penetration may be increased with further investment in standby generation. For instance some days could produce 80% intermittent wind and on the many windless days substitute 80% dispatchable power like natural gas, biomass and Hydro. • Areas with existing high levels of
hydroelectric generation may ramp up or down to incorporate substantial amounts of wind.
Norway,
Brazil, and
Manitoba all have high levels of hydroelectric generation, Quebec produces over 90% of its electricity from hydropower, and
Hydro-Québec is the largest hydropower producer in the world. The U.S. Pacific Northwest has been identified as another region where wind energy is complemented well by existing hydropower. Storage capacity in hydropower facilities will be limited by size of reservoir, and environmental and other considerations.
Connecting grid internationally It is often feasible to export energy to neighboring grids at times of surplus, and import energy when needed. This practice is common in Europe and between the US and Canada. Integration with other grids can lower the effective concentration of variable power: for instance, Denmark's high penetration of VRE, in the context of the German/Dutch/
Scandinavian grids with which it has interconnections, is considerably lower as a proportion of the total system. Hydroelectricity that compensates for variability can be used across countries. The capacity of power transmission infrastructure may have to be substantially upgraded to support export/import plans. Some energy is lost in transmission. The economic value of exporting variable power depends in part on the ability of the exporting grid to provide the importing grid with useful power at useful times for an attractive price.
Sector coupling Demand and generation can be better matched when sectors such as mobility, heat and gas are coupled with the power system. The electric vehicle market is for instance expected to become the largest source of storage capacity. This may be a more expensive option appropriate for high penetration of variable renewables, compared to other sources of flexibility. The International Energy Agency says that sector coupling is needed to compensate for the mismatch between seasonal demand and supply. Electric vehicles can be charged during periods of low demand and high production, and in some places send power back from the
vehicle-to-grid. ==Penetration==