Shielded metal arc welding equipment typically consists of a constant current
welding power supply and an electrode, with an electrode holder, a
ground clamp, and welding cables (also known as welding leads) connecting the two.
Power supply The power supply used in SMAW has constant current output, ensuring that the current (and thus the heat) remains relatively constant, even if the arc distance and voltage change. This is important because most applications of SMAW are manual, requiring that an operator hold the torch. Maintaining a suitably steady arc distance is difficult if a constant voltage power source is used instead, since it can cause dramatic heat variations and make welding more difficult. However, because the current is not maintained absolutely constant, skilled welders performing complicated welds can vary the arc length to cause minor fluctuations in the current. , MIG, Flux-Cored, & Gouging The preferred polarity of the SMAW system depends primarily upon the electrode being used and the desired properties of the weld. Direct current with a negatively charged electrode (DCEN) causes heat to build up in the parent material, decreasing the electrode melting rate and increasing the depth of the weld. Reversing the polarity so that the electrode is positively charged (DCEP) and the workpiece is negatively charged increases electrode wear and decreases the weld penetration. With alternating current the polarity changes over 100 times per second, creating an even heat distribution and providing a balance between electrode melting rate and penetration. Typically, the equipment used for SMAW consists of a
step-down transformer and for direct current models a
rectifier, which converts alternating current into direct current. Because the power normally supplied to the welding machine is high-voltage alternating current, the welding transformer is used to reduce the voltage and increase the current. As a result, instead of 220
V at 50
A, for example, the power supplied by the transformer is around 17–45 V at currents up to 600 A. A number of different types of transformers can be used to produce this effect, including multiple coil and
inverter machines, with each using a different method to manipulate the welding current. The multiple coil type adjusts the current by either varying the number of turns in the coil (in tap-type transformers) or by varying the distance between the primary and secondary coils (in movable coil or movable core transformers). Inverters, which are smaller and thus more portable, use electronic components to change the current characteristics.
Electrical generators and
alternators are frequently used as portable welding power supplies, but because of lower efficiency and greater costs, they are less frequently used in industry. Maintenance also tends to be more difficult, because of the complexities of using a combustion engine as a power source. However, in one sense they are simpler: the use of a separate rectifier is unnecessary because they can provide either AC or DC. However, the engine driven units are most practical in field work where the welding often must be done out of doors and in locations where transformer type welders are not usable because there is no power source available to be transformed. In some units, the alternator is essentially the same as that used in portable generating sets used to supply mains power, modified to produce a higher current at a lower voltage but still at the 50 or 60 Hz grid frequency. In higher-quality units, an alternator with more poles is used and supplies current at a higher frequency, such as 400 Hz. The smaller amount of time the high-frequency waveform spends near zero makes it much easier to strike and maintain a stable arc than with the cheaper grid-frequency sets or grid-frequency mains-powered units.
Electrode The choice of electrode for SMAW depends on a number of factors, including the weld material, welding position and the desired weld properties. The electrode is coated in a metal mixture called flux, which gives off gases as it decomposes to prevent weld contamination, introduces deoxidizers to purify the weld, causes weld-protecting slag to form, improves the arc stability, and provides alloying elements to improve the weld quality. Electrodes can be divided into three groups—those designed to melt quickly are called "fast-fill" electrodes, those designed to solidify quickly are called "fast-freeze" electrodes, and intermediate electrodes go by the name "fill-freeze" or "fast-follow" electrodes. Fast-fill electrodes are designed to melt quickly so that the welding speed can be maximized, while fast-freeze electrodes supply filler metal that solidifies quickly, making welding in a variety of positions possible by preventing the weld pool from shifting significantly before solidifying. The composition of the electrode core is generally similar and sometimes identical to that of the base material. But even though a number of feasible options exist, a slight difference in alloy composition can strongly impact the properties of the resulting weld. This is especially true of alloy steels such as
HSLA steels. Likewise, electrodes of compositions similar to those of the base materials are often used for welding nonferrous materials like aluminium and copper. However, sometimes it is desirable to use electrodes with core materials significantly different from the base material. For example, stainless steel electrodes are sometimes used to weld two pieces of carbon steel, and are often utilized to weld stainless steel workpieces with carbon steel workpieces. Electrode coatings can consist of a number of different compounds, including
rutile,
calcium fluoride,
cellulose, and iron powder. Rutile electrodes, coated with 25%–45% TiO2, are characterized by ease of use and good appearance of the resulting weld. However, they create welds with high hydrogen content, encouraging
embrittlement and cracking. Electrodes containing calcium fluoride (CaF2), sometimes known as basic or low-hydrogen electrodes, are
hygroscopic and must be stored in dry conditions. They produce strong welds, but with a coarse and convex-shaped joint surface.
Electrodes coated with cellulose, especially when combined with rutile, provide deep weld penetration, but because of their high moisture content, special procedures must be used to prevent excessive risk of cracking. Finally, iron powder is a common coating additive that increases the rate at which the electrode fills the weld joint, up to twice as fast. To identify different electrodes, the American Welding Society established a system that assigns electrodes with a four- or five-digit number. Covered electrodes made of mild or low alloy steel carry the prefix
E, followed by their number. The first two or three digits of the number specify the tensile strength of the weld metal, in thousand
pounds per square inch (ksi). The
penultimate digit generally identifies the welding positions permissible with the electrode, typically using the values 1 (normally fast-freeze electrodes, implying all position welding) and 2 (normally fast-fill electrodes, implying horizontal welding only). The welding current and type of electrode covering are specified by the last two digits together. When applicable, a suffix is used to denote the alloying element being contributed by the electrode. Common electrodes include the E6010, a fast-freeze, all-position electrode with a minimum tensile strength of which is operated using DCEP, and provides deep weld penetration with a forceful arc capable of burning through light rust or oxides on the workpiece. E6011 is similar except its flux coating allows it to be used with alternating current in addition to DCEP. E7024 is a fast-fill electrode, used primarily to make flat or horizontal fillet welds using AC, DCEN, or DCEP. Examples of fill-freeze electrodes are the E6012, E6013, and E7014, all of which provide a compromise between fast welding speeds and all-position welding.
Process variations Though SMAW is almost exclusively a manual arc welding process, one notable process variation exists, known as gravity welding or gravity arc welding. It serves as an automated version of the traditional shielded metal arc welding process, employing an electrode holder attached to an inclined bar along the length of the weld. Once started, the process continues until the electrode is spent, allowing the operator to manage multiple gravity welding systems. The electrodes employed (often E6027 or E7024) are coated heavily in flux, and are typically in length and about thick. As in manual SMAW, a constant current welding power supply is used, with either negative polarity direct current or alternating current. Due to a rise in the use of semiautomatic welding processes such as flux-cored arc welding, the popularity of gravity welding has fallen as its economic advantage over such methods is often minimal. Other SMAW-related methods that are even less frequently used include firecracker welding, an automatic method for making butt and fillet welds, and massive electrode welding, a process for welding large components or structures that can deposit up to of weld metal per hour. ==Notes==