Purified water is suitable for many applications, including autoclaves, hand-pieces, laboratory testing, laser cutting, and automotive use. Purification removes contaminants that may interfere with processes, or leave residues on evaporation. Although water is generally considered to be a good electrical conductor—for example, domestic electrical systems are considered particularly hazardous to people if they may be in contact with wet surfaces—
pure water is a poor conductor. The conductivity of water is measured in Siemens per meter (S/m). Sea-water is typically 5 S/m, drinking water is typically in the range of 5-50 mS/m, while highly purified water can be as low as 5.5 μS/m (0.055 μS/cm), a
ratio of about 1,000,000:1,000:1. Purified water is used in the pharmaceutical industry. Water of this grade is widely used as a raw material, ingredient, and solvent in the processing, formulation, and manufacture of pharmaceutical products, active pharmaceutical ingredients (APIs) and intermediates, compendial articles, and analytical reagents. The microbiological content of the water is of importance and the water must be regularly monitored and tested to show that it remains within microbiological control. Purified water is also used in the commercial beverage industry as the primary ingredient of any given trademarked bottling formula, in order to maintain critical consistency of taste, clarity, and color. This guarantees the consumer reliably safe and satisfying drinking. In the process prior to filling and sealing, individual bottles are always rinsed with deionised water to remove any particles that could cause a change in taste. Deionised and distilled water are used in lead–acid batteries to prevent erosion of the cells, although deionised water is the better choice as more impurities are removed from the water in the creation process.
Laboratory use Technical standards on water quality have been established by a number of professional organizations, including the
American Chemical Society (ACS),
ASTM International, the U.S. National Committee for Clinical Laboratory Standards (NCCLS) which is now
CLSI, and the
U.S. Pharmacopeia (USP). The ASTM, NCCLS, and ISO 3696 or the
International Organization for Standardization classify purified water into Grade 1–3 or Types I–IV depending on the level of purity. These organizations have similar, although not identical, parameters for highly purified water. Note that the
European Pharmacopeia uses Highly Purified Water (HPW) as a definition for water meeting the quality of Water For Injection, without however having undergone distillation. In the laboratory context, highly purified water is used to denominate various qualities of water having been "highly" purified. Regardless of which organization's water quality norm is used, even Type I water may require further purification depending on the specific laboratory application. For example, water that is being used for molecular-biology experiments needs to be
DNase or
RNase-free, which requires special additional treatment or functional testing. Water for microbiology experiments needs to be completely sterile, which is usually accomplished by autoclaving. Water used to analyze trace metals may require the elimination of trace metals to a standard beyond that of the Type I water norm.
Criticism A member of the ASTM D19 (Water) Committee, Erich L. Gibbs, criticized ASTM Standard D1193, by saying "Type I water could be almost anything – water that meets some or all of the limits, part or all of the time, at the same or different points in the production process."
Electrical conductivity Completely de-gassed ultrapure water has a conductivity of 1.2 × 10−4 S/m, whereas on equilibration to the atmosphere it is 7.5 × 10−5 S/m due to dissolved CO2 in it. The highest grades of ultrapure water should not be stored in glass or plastic containers because these container materials leach (release) contaminants at very low concentrations. Storage vessels made of
silica are used for less-demanding applications and vessels of ultrapure
tin are used for the highest-purity applications. Although electrical conductivity only indicates the presence of ions, the majority of common contaminants found naturally in water ionize to some degree. This ionization is a good measure of the efficacy of a filtration system, and more expensive systems incorporate conductivity-based alarms to indicate when filters should be refreshed or replaced. For comparison, seawater has a conductivity of perhaps 5 S/m (53 mS/cm is quoted), while normal un-purified tap water may have conductivity of 5 × 10−3 S/m (50 μS/cm) (to within an order of magnitude), which is still about 2 or 3 orders of magnitude higher than the output from a well-functioning demineralizing or distillation mechanism, so low levels of contamination or declining performance are easily detected.
Industrial uses Some industrial processes, notably in the semiconductor and pharmaceutical industries, need large amounts of very pure water. In these situations, feedwater is first processed into purified water and then further processed to produce
ultrapure water. Another class of ultrapure water used for pharmaceutical industries is called Water-For-Inject (WFI), typically generated by multiple distillation or compressed-vaporation process of DI water or RO-DI water. It has a tighter bacteria requirement as 10 CFU per 100 mL, instead of the 100 CFU per mL per USP.
Other uses Distilled or deionized water is commonly used to top up the
lead–acid batteries used in cars and trucks and for other applications. The presence of foreign ions commonly found in tap water will drastically shorten the lifespan of a lead–acid battery. Distilled or deionized water is preferable to tap water for use in automotive cooling systems. Using deionised or distilled water in appliances that evaporate water, such as
steam irons and humidifiers, can reduce the build-up of mineral
scale, which shortens appliance life. Some appliance manufacturers say that deionised water is no longer necessary. Purified water is used in freshwater and marine
aquariums. Since it does not contain impurities such as copper and chlorine, it helps to keep fish free from diseases and avoids the build-up of algae on aquarium plants due to its lack of phosphate and silicate. Deionized water should be re-mineralized before use in aquaria since it lacks many macro- and micro-nutrients needed by plants and fish. Water (sometimes mixed with
methanol) has been used to extend the performance of aircraft engines. In piston engines, it acts to delay the onset of
engine knocking. In turbine engines, it allows more fuel flow for a given turbine temperature limit and increases mass flow. As an example, it was used on early
Boeing 707 models. Advanced materials and engineering have since rendered such systems obsolete for new designs; however, spray-cooling of incoming air-charge is still used to a limited extent with off-road turbo-charged engines (road-race track cars). Deionized water is very often used as an ingredient in many cosmetics and pharmaceuticals. "Aqua" is the standard name for water in the
International Nomenclature of Cosmetic Ingredients standard, which is mandatory on product labels in some countries. Because of its high relative
dielectric constant (~80), deionized water is also used (for short durations, when the resistive losses are acceptable) as a high voltage dielectric in many
pulsed power applications, such as the
Sandia National Laboratories Z Machine. Distilled water can be used in PC water-cooling systems and Laser Marking Systems. The lack of impurity in the water means that the system stays clean and prevents a buildup of bacteria and algae. Also, the low conductance reduces the risk of electrical damage in the event of a leak. However, deionized water has been known to cause cracks in brass and copper fittings. When used as a rinse after washing cars, windows, and similar applications, purified water dries without leaving spots caused by dissolved solutes. Deionized water is used in water-fog fire-extinguishing systems used in sensitive environments, such as where high-voltage electrical and sensitive electronic equipment is used. The 'sprinkler' nozzles use much finer spray jets than other systems and operate at up 35 MPa (350 bar; 5,000 psi) of pressure. The extremely fine mist produced takes the heat out of fire rapidly, and the fine droplets of water are nonconducting (when deionized) and are less likely to damage sensitive equipment. Deionized water, however, is inherently acidic, and contaminants (such as copper, dust, stainless and carbon steel, and many other common materials) rapidly supply ions, thus re-ionizing the water. It is not generally considered acceptable to spray water on electrical circuits that are powered, and it is generally considered undesirable to use water in electrical contexts. Distilled or purified water is used in
humidors to prevent
cigars from collecting
bacteria,
mold, and contaminants, as well as to prevent residue from forming on the
humidifier material. Window cleaners using water-fed pole systems also use purified water because it enables the windows to dry by themselves leaving no stains or smears. The use of purified water from water-fed poles also prevents the need for using ladders and therefore ensure compliance with Work at Height Legislation in the UK. ==Mineral consumption==