Support Support is the principle that describes how well the underlying mucosa (oral tissues, including gums) keeps the denture from moving vertically towards the arch in question during chewing, and thus being excessively depressed and moving deeper into the arch. For the mandibular arch, this function is provided primarily by the buccal shelf, a region extending
laterally from the back or posterior ridges, and by the pear-shaped pad (the most posterior area of keratinized gingival formed by the scaling down of the retro-molar papilla after the extraction of the last molar tooth). Secondary support for the complete mandibular denture is provided by the alveolar ridge crest. The maxillary arch receives primary support from the horizontal hard palate and the posterior alveolar ridge crest. The larger the denture flanges (that part of the denture that extends into the
vestibule), the better the stability (another parameter to assess fit of a complete denture). Long flanges beyond the functional depth of the
sulcus are a common error in denture construction, often (but not always) leading to movement in function, and ulcerations (denture sore spots).
Stability Stability is the principle that describes how well the denture base is prevented from moving in a horizontal plane, and thus sliding from side to side or front to back. The more the denture base (pink material) is in smooth and continuous contact with the edentulous ridge (the hill upon which the teeth used to reside, but now only residual alveolar bone with overlying mucosa), the better the stability. Of course, the higher and broader the ridge, the better the stability will be, but this is usually a result of patient anatomy, barring surgical intervention (bone grafts, etc.).
Retention Retention is the principle that describes how well the denture is prevented from moving vertically in the opposite direction of insertion. The better the topographical mimicry of the intaglio (interior) surface of the denture base to the surface of the underlying mucosa, the better the retention will be (in
removable partial dentures, the clasps are a major provider of retention), as surface tension, suction and friction will aid in keeping the denture base from breaking intimate contact with the mucosal surface. It is important to note that the most critical element in the retentive design of a maxillary complete denture is a complete and total border seal (complete peripheral seal) in order to achieve 'suction'. The border seal is composed of the edges of the anterior and lateral aspects and the posterior palatal seal. The posterior palatal seal design is accomplished by covering the entire hard palate and extending not beyond the soft palate and ending 1–2 mm from the vibrating line. Prosthodontists use a scale called the Kapur index to
quantify denture stability and retention. Implant technology can vastly improve the patient's denture-wearing experience by increasing stability and preventing bone from wearing away. Implants can also aid retention. Instead of merely placing the implants to serve as blocking mechanism against the denture's pushing on the alveolar bone, small retentive appliances can be attached to the implants that can then snap into a modified denture base to allow for tremendously increased retention. Available options include a metal "Hader bar" or precision ball attachments.
Fit, maintenance and relining Generally speaking, partial dentures tend to be held in place by the presence of the remaining natural teeth and complete dentures tend to rely on muscular co-ordination and limited suction to stay in place. The maxilla very commonly has more favorable denture-bearing anatomy, as the ridge tends to be well formed and there is a larger area on the palate for suction to retain the denture. Conversely, the mandible tends to make lower dentures much less retentive due to the displacing presence of the tongue and the higher rate of resorption, frequently leading to significantly resorbed lower ridges. Disto-lingual regions tend to offer retention even in highly resorbed mandibles, and extension of the flange into these regions tends to produce a more retentive lower denture. An implant supported lower denture is another option for improving retention. Dentures that fit well during the first few years after creation will not necessarily fit well for the rest of the wearer's lifetime. This is because the bone and mucosa of the mouth are living tissues, which are dynamic over decades.
Bone remodeling never stops in living bone.
Edentulous jaw ridges tend to
resorb progressively over the years, especially the alveolar ridge of the lower jaw. Mucosa reacts to being chronically rubbed by the dentures. Poorly fitting dentures hasten both of those processes compared to the rates with well-fitting dentures. Poor fitting dentures may also lead to the development of conditions such as
epulis fissuratum. In addition, the
occlusion (chewing surfaces of the teeth) tends to wear away over time, which reduces chewing efficacy and decreases the
vertical dimension of occlusion (the "openness" of the jaws and mouth). == Costs ==